MASCO Catalog: Concrete Forming & Accessories

194 MASONS SUPPLY COMPANY Oregon (800) 537-3407 ♦ Washington (800) 537-6216 Clackamas | Eugene | West Eugene | Hillsboro | Medford | Portland | Salem | Ridgefield | Seattle | Tacoma | Woodinville M A S C O . N E T TILT-UP/PRECAST TILT-UP Set Body Lid T-90-E Edge Lift Insert Has an integral shear plate for maximum transfer of shear load into the concrete. The insert is furnished with a disposable recess plug that is used to attach the assembly to the panel form. Make certain that the crane applies the lifting load in a direction toward the top of the panel or perpendicular to the casting bed. DO NOT allow the crane to apply a load toward the bottom of the panel. SWL provides a factor of safety of approximately 2 to 1 in 2,500 psi normal weight concrete. Consult manufacturers data on values on shear and reduced edge distance. The crane line should be slackened slightly to permit the release of the lifting hardware. To release the hardware, apply a quick, even downward force to the release line. T-90-E Edge Lift Insert T-90-C Rebar Clip Structural Panel Thickness Shear Safe Working Load (lbs.) Tension Safe Working Load (lbs.) 4" 4,300 4,700 5" 5,250 5,900 6" 6,200 7,000 7" 7,050 8,200 T-90 Edge LIft Chart: No. Size Wt (lbs) DS FL147 2 ton 2.25 DS FL148 4 ton 5.41 DS FL149 8 ton 10.50 P-99-D Disposal Recess Plug Top of Panel Top of Panel Top of Panel Tilt-Up 3 Hardware in open position. Hardware nested in the insert void and Bolt/Release arm engaged. Installation Completed.

RkJQdWJsaXNoZXIy MTIxNDc=